For automotive repair experts and workshops specializing in Mercedes-Benz vehicles, Xentry Open Shell is an indispensable diagnostic software. This powerful tool allows for in-depth vehicle diagnostics, programming, and troubleshooting. However, the installation process can sometimes be complex. This guide provides a detailed, step-by-step walkthrough on How To Install Xentry Open Shell, ensuring a smooth setup for your diagnostic needs.
This guide is specifically designed to enhance the original instructions, offering greater clarity, SEO optimization, and a focus on the practical needs of automotive professionals. We aim to provide a helpful and authoritative resource, reflecting expertise and experience in automotive software installation.
Prerequisites Before Installation
Before you begin the Xentry Open Shell installation, ensure you have the following:
- Xentry Open Shell Software Package: This guide assumes you have the software package provided by xentryportal.store. Note that specific versions might have slight variations in installation steps.
- Windows PC: Xentry Open Shell is compatible with Windows operating systems. Ensure your PC meets the minimum system requirements for optimal performance.
- Disable Secure Boot: Crucially, before starting, access your computer’s BIOS settings and disable the “Secure Boot” option. This step is essential for Windows 10 systems and later to allow for proper installation.
Step-by-Step Xentry Open Shell Installation Guide
Follow these steps carefully to install Xentry Open Shell successfully:
Step 1: Initiate the Installation Process
Navigate to the downloaded Xentry Open Shell software package folder, typically named “XDS_[Version Number]”. Locate and double-click the “start” application file. This action will initiate the installation process.
Step 2: Language Selection
You will be prompted to select your preferred language for the installation process. Choose your language from the available options and proceed.
Step 3: InstallShield Wizard and Prerequisites
XENTRY Diagnostic OpenShell requires several prerequisite components to be installed on your computer. The installation wizard will identify these necessary items. Click “Install” to begin installing these prerequisites.
The InstallShield Wizard will then launch to guide you through the main XENTRY Diagnostic OpenShell installation. Click “Next” to continue.
Follow the on-screen prompts, clicking “Next” to advance through each step. You will be presented with a license agreement. Accept the terms and click “Next” to proceed.
Step 4: Installation Destination
You will be prompted to choose an installation location. It is highly recommended to install Xentry to the default directory suggested by the wizard. Simply click “Next” to accept the default location.
Click “Next” again to confirm your settings and proceed to the next stage.
Step 5: Begin the Installation
Finally, click “Install” to initiate the main XENTRY Diagnostic OpenShell installation process.
Step 6: Waiting for Installation Completion
The installation process will now begin, and the InstallShield Wizard will display a progress bar. This process can take a significant amount of time, often exceeding two hours, depending on your computer’s processing speed and performance.
Allow the installation to complete without interruption. Once all modules are installed, you will be prompted to restart your PC. Follow the prompt and restart your computer.
After restarting, the ConfigAssist application may launch automatically. Close ConfigAssist as it will be configured later.
Step 7: ConnectorAPI Configuration
Navigate to the “ConnectorAPI” folder within your Xentry Open Shell software package.
- Copy
ConnectorAPI64.dll
: Copy this file toC:WindowsSystem32
. - Run
64.reg
: Double-click the “64.reg” file to add its contents to your Windows Registry. Confirm the action by clicking “OK” when prompted.
Step 8: XentryAPI.dll and Registry Setup
Open the “SysWOW64” folder within the Xentry Open Shell package.
-
Copy
XentryAPI.dll
: Copy this file and paste it intoC:WindowsSysWOW64
. -
Run
old key loader for configassist or startkeycenter 64bit.reg
: Double-click this registry file and click “OK” to add its settings to the registry.
Step 9: Execute XDOS Black List
Run the “XDOS black list.exe” application located in the main software package. Click “Extract” to execute the blacklist.
Step 10: Copy Baureihen Pictures
Copy the contents of the “Baureihen” folder to the following directory: C:Program Files (x86)Mercedes-BenzXentryKontexteProduktuebersichtBilderBaureihen
. This step ensures proper display of vehicle model series images within Xentry.
Step 11: Configure GlobalUserSettings
Navigate to C:ProgramDataMercedes-Benzconfig
. Create a new folder named “Xentry” if it doesn’t already exist.
Then, go to C:ProgramDataMercedes-BenzconfigXD_MB
. Copy the file named “GlobalUserSettings.properties” to the newly created C:ProgramDataMercedes-BenzconfigXentry
folder.
Step 12: Activate Xentry with StartKey
Now you can run ConfigAssist to proceed with the activation of Xentry Open Shell.
-
Hardware ID: Copy your Hardware ID and contact ECUTOOL at <[email protected]> to request your StartKey code. Please note that obtaining the activation key is a paid service.
For users seeking self-activation options, consider purchasing the XENTRY Advanced KeyGen 1.1 Long Key.
-
Manual Activation: In ConfigAssist, click “Manual”. Enter the StartKey code provided by ECUTOOL.
-
Save Activation: Click “Save” to finalize the StartKey installation.
A confirmation message will indicate successful StartKey installation.
Step 13: Modify XentryServices.xml (for older versions)
Note: For Xentry versions 12.2023 and later, skip this step and proceed to Step 14.
- Locate and Cut
XentryServices.xml
(XD_MB): Go toC:Program Files (x86)Mercedes-BenzXentryXD_MBbin
. Cut the “XentryServices.xml” file and paste it to your Desktop. - Edit
XentryServices.xml
: Open the file on your Desktop with Notepad. Locate and delete the specified line (refer to your specific version’s instructions for the exact line). Save the modified file. - Replace
XentryServices.xml
(XD_MB): Cut the modified “XentryServices.xml” file from your Desktop and paste it back intoC:Program Files (x86)Mercedes-BenzXentryXD_MBbin
, replacing the original file. - Repeat for XD_DT (if applicable): If your instructions specify modification for XD_DT as well, repeat steps 1-3 for the
XentryServices.xml
file located inC:Program Files (x86)Mercedes-BenzXentryXD_DTbin
.
Step 14: Backup and Run Xentry
- Copy
Backup.bat
: Copy the “Backup.bat” file from the downloaded software package to yourC:
drive. - Run
Backup.bat
: Double-click “Backup.bat” to run it. This will generate alic_key_2.dat
file in your C: drive. Do not delete this file. - Copy
start_Xentry.bat
: Copy the “start_Xentry.bat” file toC:Program Files (x86)Mercedes-BenzXentryXD_MB
. - Create Shortcut: Right-click on “start_Xentry.bat” in the
XD_MB
directory and select “Send to” -> “Desktop (create shortcut)”.
Important: Always use the newly created “start_Xentry” shortcut on your desktop to launch Benz Xentry, instead of using other methods.
Completion and Troubleshooting
Congratulations! Xentry Open Shell installation and activation are now complete. You can now launch Xentry using the “start_Xentry” shortcut on your desktop.
Exiting Xentry: To properly exit Xentry, double-click the “Diagnosis Stop” icon on your desktop.
Troubleshooting Common Issues:
- “2221-45 No access authorization” Error: Refer to specific troubleshooting guides for this error code, often related to license or activation issues.
- SmartKey Invalid Error: If you encounter a SmartKey invalid error, revisit your BIOS settings and ensure “Secure Boot” is disabled.
This comprehensive guide provides detailed steps on how to install Xentry Open Shell. By following these instructions carefully, automotive professionals can successfully set up this essential diagnostic tool and enhance their Mercedes-Benz repair capabilities. For further assistance with activation keys or advanced configurations, please contact <[email protected]>.