Xentry DAS 01-2011 Download and Installation Guide for Mercedes-Benz Diagnostics

For automotive repair professionals and Mercedes-Benz enthusiasts, having access to diagnostic software like Xentry DAS is crucial. This guide provides a step-by-step walkthrough on how to install Xentry DAS 01-2011, enabling you to perform comprehensive diagnostics on Mercedes-Benz vehicles. While this guide is based on a virtual machine setup, the process is equally applicable to a laptop or desktop environment.

Preparing for Xentry DAS 01-2011 Installation

Before you begin the installation of Xentry DAS 01-2011, careful preparation is key to a smooth process. This involves partitioning your hard drive and setting up the necessary user accounts.

  1. Partition Manager Installation: Start by installing a partition manager. This tool will allow you to create dedicated partitions for the Xentry DAS software, ensuring it runs efficiently and without conflicts with your main operating system.

  2. Disable DVD Drive (Temporarily): For a streamlined partition lettering process, temporarily disable your DVD drive. This step helps in assigning drive letters correctly to your newly created partitions right from the outset.

  3. Create Partitions: Using the partition manager, create the necessary partitions. A dedicated partition ensures that Xentry DAS and its associated files are isolated, contributing to system stability and performance.

  4. Create “STAR” Account: Establish a user account named “STAR”. This account will be used during the installation and operation of Xentry DAS, helping to keep the diagnostic environment separate from your regular user environment.

  5. Enable DVD Drive: Once the partitions and user account are set up, re-enable your DVD drive. You will need it to access the Xentry DAS installation media.

Installing Xentry DAS 01-2011

With the groundwork laid, you can proceed with the core installation steps for Xentry DAS 01-2011.

  1. Login and Prepare Installation: Log in using the “STAR” account you created. Prepare for the installation using dedicated tools, which streamline the setup process. These tools are designed to automate certain steps and ensure compatibility.

  2. Enter DAS Key: When prompted, input your DAS key. This key is essential for authenticating your software and enabling full functionality.

  3. Install DAS (Wait Patiently): Initiate the DAS installation process. This is a lengthy process, so patience is crucial. Even if it seems like the installation is stuck or unresponsive, allow it to continue. Interrupting the process can lead to installation failures.

  4. Post-Installation Script: Upon receiving the “Setup complete” message, do not immediately click “Finish.” Instead, navigate to the designated tools folder and run the “after_installation.bat” script. This script performs crucial post-installation tasks. Only after running this script should you click “Finish.”

  5. Disable Automatic Hotfix Installation: To maintain system stability and prevent unwanted updates, disable automatic hotfix installations. This ensures that your diagnostic environment remains consistent.

  6. Disable Online Update BG Service: Similarly, disable the Online Update BG service. This prevents background updates that could potentially interfere with the operation of Xentry DAS.

Installing and Activating Xentry 01-2011

The next phase involves installing Xentry and performing the necessary activation steps to get it fully operational.

  1. Install Xentry & Activation: Begin the Xentry installation process. During this stage, you need to be attentive and perform a crucial manual step. Navigate to the directory F:\Programme\Xentry\bin and delete the UserConfig.xml file as soon as it is created during the installation. Note that “bin” is often a hidden folder, so ensure hidden folders are visible in your folder options. Failing to delete this file can cause the installation to hang indefinitely, typically with a message about creating folders and icons. If this happens, use Task Manager to terminate the installation process and restart the Xentry installation, repeating this file deletion step.

For activation, older Xentry keys might not work directly with version 01-2011. However, workarounds and solutions are often available. These may involve replacing specific DLL files or using executable tools designed to patch the software and bypass license checks. It’s important to source these solutions from reputable communities and forums specializing in automotive diagnostic software.

  1. COM Port Settings: Configure the COM port settings to ensure proper communication between your diagnostic interface and the Xentry DAS software. Correct COM port configuration is vital for establishing a reliable connection with the vehicle.

  2. Edit cal.ini File: Navigate to C:\Programme\DAS\Bin\ and locate the cal.ini file. Open this file and find the line PLATFORM=PART_W. Change this line to PLATFORM=PART_D2. This modification is necessary for correct system configuration. Alternatively, you might find pre-edited cal.ini files specifically for 01-2011 versions from online resources.

Alt text: Installation process of DAS Xentry 09-2010 showcasing partition setup, account creation, and software installation steps, emphasizing key stages for Mercedes-Benz diagnostic software setup.

Troubleshooting Common Installation Errors

Users occasionally encounter errors during the installation process. One reported issue involves error code -6003, often accompanied by messages about driver repair failures and license authorization problems. These errors can stem from various factors, including incomplete installations, incorrect keys, or software conflicts.

Error Code -6003 and License Issues: This error sometimes points to problems with license authorization or incomplete setup. Double-check the license keys provided and ensure they are correctly entered for both DAS and Xentry. The “AppID” mentioned in error messages should also be verified against the expected values for the 01-2011 version.

“Save Not Successfully” License Errors: If you encounter “Save not successfully” errors related to license checks, especially with messages like “Liccheklicense xentry diagnostic – starkey can not be decoded,” it often indicates an incompatibility between the license key, the Xentry version, or the activation method being used. For 01-2011, ensure you are using activation methods and keys specifically designed for this version. Older keys or activation methods might not be compatible.

Awesome Xentry Solution Files Not Executing: Solutions and patch files designed for older versions of Xentry might not work with 01-2011. Always verify the compatibility of any solution files with your specific Xentry DAS 01-2011 version. Consult forums and communities to find version-specific fixes and activation methods.

Conclusion

Successfully installing Xentry DAS 01-2011 requires careful adherence to each step, from initial preparation to final activation. By following this guide, you should be well-equipped to set up this powerful diagnostic tool for Mercedes-Benz vehicles. Remember to be patient during the installation process, pay close attention to detail, and seek out community resources if you encounter specific errors. With Xentry DAS 01-2011 properly installed, you’ll have a robust platform for diagnosing and servicing Mercedes-Benz vehicles effectively.